EDACS
®
CONVENTIONAL NETWORK INTERFACE (CNI)
GETC CONFIGURATION MANUAL
TABLE OF CONTENTS
SPECIFICATIONS* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SOFTWARE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
RELATED PUBLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
INTERFACE TO EDACS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CONSOLE PREEMPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHANNEL GUARD MAPPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
MAPPING WITHOUT CHANNEL GUARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
EQUIPMENT REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
HARDWARE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Logic Board Modification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Rockwell Modem Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Turbo Board Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
GETC Cable Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Jumper Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
GETC FIRMWARE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
EPROM Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TURBO SOFTWARE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Programming Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
PERSONALITY PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Programming Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Programming the Personality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
REPEATER PERSONALITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
DIP SWITCH SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
MODEM ALIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CEC/IMC PERSONALITY CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
LBI-38986
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - LBI-38986

EDACS®CONVENTIONAL NETWORK INTERFACE (CNI)GETC CONFIGURATION MANUALTABLE OF CONTENTSSPECIFICATIONS* . . . . . . . . . . . . . . . . .

Pagina 2

GETC Cable ModificationsUse the following procedures to modify and reconnectcables in the CNI GETC. Be sure to follow the correctprocedures. Instruc

Pagina 3 - INTRODUCTION

2. Remove the contacts (4) from the header (P26) onthe harness 19C337792P1.3. Remove contacts from 19B802401P1, P6-8 andP6-9. This is the GETC Transm

Pagina 4 - SOFTWARE REQUIREMENTS

This procedure provides instructions for programmingthe Turbo Board installed in the CNI GETC. Theinstallation process uses the software diskette 344

Pagina 5 - OPERATION

Figure 7 - CNI GETC (19D904266) Jumper LocationsFigure 8 - Turbo Board ProgrammingLBI-3898613

Pagina 6 - INSTALLATION

Table 2 - Jumper SettingsJumper setting for CNI GETC (19D904266 ONLY).JumperPositionWidebandCNIGETCNarrow bandCNIGETC FUNCTIONP11 1&2 1&2 Enab

Pagina 7

1. Move switches S2 and S3 to the "run" position(toward the back of the GETC shelf).2. Press S4 to reset the GETC.3. The Turbo Board LEDs,

Pagina 8

3. Following the instructions in TQ-3357, select the"GE" directory and execute the "GTC" command. After a brief introductory scre

Pagina 9

REPEATER PERSONALITYIt may be necessary to reprogram the personality of theMASTR III or IIe repeater. Refer to TQ-3353 (Version 9.0or later). Select

Pagina 10

Figure 12 - GETC Phone Line Level AdjustmentsLBI-3898618

Pagina 11

Figure 13 - Sample CNI PersonalityLBI-3898619

Pagina 12

TABLE OF CONTENTS - Cont.LED INDICATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 13

CEC/IMC PERSONALITYCONFIGURATIONAt the System Manager (refer to LBI-38984), configurethe CNI groups as TRACKED. This enables the CEC/IMCto route only

Pagina 14

2. Verify the CNI GETC LED’s indicate the Idle State(see Table 3), L1 is ON, L2 thru L7 are OFF. (IfNarrow Band repeater, L3 is also ON).3. Initiate

Pagina 15 - CONFIGURATION

Apply an additional 1000 Hz tone at 0 dBm. Verify the output deviation of the transmitter is3.75 kHz • 100 Hz. If necessary, adjust POT 7,Compressor

Pagina 16

4. Check CEC/IMC Switch Audio connections.• This refers to audio connections between theCEC/IMC Switch and the CNI GETC orRepeater. Refer to CEC/IMC

Pagina 17

CEC/IMC Data signals:Data Rate 9600 baudTransmit level 0.77 VrmsReceive level 0.16 Vrms on J3A-32(U18A-1)Repeater Configurations:For Four Wire Tone R

Pagina 18

Figure 14 - CNI Troubleshooting ChartTROUBLESHOOTING CHARTLBI-3898625

Pagina 19

INTERCONNECT DIAGRAMFigure 15 - Typical CNI to Conventional Repeater InterfaceLBI-3898626

Pagina 20 - TEST AND ALIGNMENT

INTERCONNECT DIAGRAMMASTR III STATIONSIMPLIFIED INTERCONNECT DIAGRAMLBI-3898627

Pagina 21

INTERCONNECTION DIAGRAMMASTR II, IIe STATIONSIMPLIFIED INTERCONNECT DIAGRAMLBI-3898628

Pagina 22 - TROUBLESHOOTING

INSTALLATION DIAGRAMCNI GETC SHELFMASTR III INSTALLATIONSXCP5T(19D902845, Sh. 30, Rev. 1)LBI-3898629

Pagina 23

SCOPEThe Conventional Network Interface (CNI) provides thecommunication link between a conventional repeater(MASTR II, IIe, or III) and an Enhanced Di

Pagina 24

INSTALLATION DIAGRAMCNI GETC SHELFMASTR II, IIe INSTALLATIONSTCP3Z(19D417483, Sh. 12, Rev. 27)When installing GETC Panel 19D901868,Mount GETC Panel ab

Pagina 25

tion stored in the CNI GETC personality EEPROM. Whena conventional transmission is received, the GETC decodesthe analog Channel Guard tones and assoc

Pagina 26 - INTERCONNECT DIAGRAM

RELATED PUBLICATIONSIt may be necessary to consult one or more of thefollowing documents during the installation process. Thesemanuals will also prov

Pagina 27

The CNI GETC also performs data error detection andcorrection, general control of timer and I/O functions (DIPswitch, LED’s, UART’s, etc.), receive an

Pagina 28 - INTERCONNECTION DIAGRAM

EQUIPMENT REQUIREDThe following equipment and software may be requiredto modify and configure the CNI GETC:IBM compatible PC with at least 640K memory

Pagina 29 - INSTALLATION DIAGRAM

Rockwell Modem InstallationThe Rockwell Modem provides a high speedsynchronous serial interface between the CNI GETC andthe CEC/IMC’s Uplink. The CN

Pagina 30

2. Isolate the modem from the shelf by installing theeight (8) fiber washers (4035306P25, part ofHardware Kit 344A4019). Insert four (4) washersbetwe