Conditional Access
Figure D.17 EMM Dialog Box [Private Data Tab]
D.7.3 Checking the ECM Generator Status (Scheduling the Profile)
Table D.9 describes the procedure for checking the status.
Table D.9 Checking the ECMG Status
Step Action Result Comments
1
After configuring the
ECMs and EMMs,
schedule the profile.
Telnet into port 34 of the MX8400.
Check the outgoing TS on a STB and on a TS
analyser.
2 Go to ECMG status
The control is shown
changing from ODD
to EVEN every 10
seconds
Option l on the Simulcrypt CA Params menu
3
Check Equipment Status
Monitor and the
nCompass Control
server window for error
messages
If there are any problems, check and recheck
all the MX8400 settings, all the physical map
settings, and all the profile manager settings.
2/1553-FGC 101 1014 Uen B