LBI-39040 CONFIGURATION FILES
20
Selecting E1 or T1 in Table 3 automatically sets the appropriate values for the entries in Table 13 below.
Table 13 - PI Trunk Parameters
Variable Name Use Allowed Values
TRUNK_CLOCK_SOURCE Clock source for trunk framing. RECOVER_MD110_TRUNK
RECOVER_MUX_TRUNK
INTERNAL_CLK
EXTERNAL_CLK
default = RECOVER_MD110_TRUNK
MUX_TRUNK_FRAMING Framing type selection for
multiplexer trunk.
ESF
ESF_ZBTSI
SF
SF_SLC96
CRC4
default = ESF
MUX_TRUNK_CODING Coding type selection for
multiplexer trunk.
B8ZS
B7ZS
AMI
HDB3
default = B8ZS
MD110_TRUNK_FRAMING Framing type selection for MD110
trunk.
ESF
ESF_ZBTSI
SF
SF_SLC96
default = ESF
MD110_TRUNK_CODING Coding type selection for MD110
trunk.
B8ZS
B7ZS
AMI
HDB3
default = B8ZS
Q931_CONNECTION_TYPE Defines the Q.931 layer of PABX
Interface as seen by the MD110.
ATT4ESS_USER
ATT5ESS_USER
NTI_USER
ATT4ESS_NETWORK
ATT5ESS_NETWORK
NTI_NETWORK
CEPT
default = ATT5ESS_USER