LBI-38987B CONFIGURATION
18
TQ-3357 V4.03 (or later)
1. Connect the TQ-3360 programming cable from the
PC's serial port connector to the GETC Shelf
connector J104 (A DB-25 to DB-9 adapter may be
needed.)
2. Using the TQ-3357’s LOAD utility, copy the
Station Turbo software (344A4414) into the PC
Programmer’s working directories.
3. Load the Field Macro “gtc_9505.mac” into the
TQ-3357 PC Programmer using the instructions
contained in Chapter 5 of the TQ-3357 manual.
4. Refer to TQ-3357 Chapter 5 Load1E Utility for
complete instructions on downloading the Turbo
software .
TQ-3357 V3 (or earlier)
1. Connect the TQ-3360 programming cable from the
PC's serial port connector to the GETC Shelf
connector J100 (A DB-25 to DB-9 adapter may be
needed.)
2. Using standard DOS commands or a software file
manager, create a directory named "LOAD1E" on
the PC's hard drive.
3. Make "LOAD1E" the current directory and copy
the following files from the software diskette into
the "LOAD1E" directory:
• load1e.exe
• 1etop.hex
• 1ecrc.hex
• 1ebot.hex
4. Run the load1e.exe program. Follow the on screen
instructions and program the Turbo Board.
Additional programming instructions may be found
in SRN1062 and LBI-38822.
NOTE
When using Turbo Board 344A4414 Group 2 (or
later) software, re-programming the GETC Turbo
Board will not alter previously stored Personality
Data. When Personality Data is present,
“load1e.exe” clears and performs CRC functions
over the code portion of memory only.
NOTE
Comentarios a estos manuales