Communications systems built to drive business ahead
MD Evolution 8.1
Product News
17
PN 06:16 Rev A 2006-10-20
Created by ESF/KEP/MA Francois Vaillant
CTA Boards cabling. Connecting each PSTN line on to the CTA Board is
achieved using a single pair cable. This cable must be terminated with a HE14
type 4-pin female connector on the CTA side (only two pins are connected).
Female connectors are provided with the basic system.
CTA compatibility with the installed base
The MD Evolution M/Mi system shall be equipped with the CPU board CPJ3G,
CPJ4, CPJ5 or CPJ6 and supporting the MDE 8.1 software or later. The CPU
DSP firmware requires an updating to get the CLIP service on the analogue
trunks. Refer section "Software deliverable" for available DSP versions.
The CTA board can be plugged in any slot of the system. It does not require
the Expansion software license.
Migration from a MDE-M/Mi system equipped with an analogue trunk to a
MDE-XL/Xli system. What are the differences in terms of services available on
the analogue trunk?
o the CLIP service on analogue trunk is available on the MDE-
M/Mi, and not on the MDE-XL/Xli
o The service "selective trunk" is available on the MDE-XL/Xli
and not on the MDE-M/Mi systems.
o All the other parameters for the analogue trunk and for the
trunk group are the same in both systems.
5.2 New CCS4-S power supply for MD Evolution
M/Mi
CCS4-S Board Role and Functions
The new power supply CCS4-S is used to directly power the MDE-M/Mi system from a
100-240 Volts, 50-60 Hz mains source which can be possibly backed-up from a
battery that, according to its capacity and the system cabinet type, can be either
integrated into the system cabinet or be externally installed.
The CCS4-S is delivered with the European mains power cable. Two specific cables
can be ordered separately: one for the UK market and one for the North American
markets.
From the mains source (tolerances 90 - 265 Volts, 42 - 68 Hz), which input is protected
by fuses, CCS4-S board delivers all secondary voltages needed to supply the system
boards (+ 5 VDC, + 3 VDC and - 5 VDC voltages), as well as the -40 VDC voltage to
remotely powering all DIALOG 3000 or DIALOG 4000 digital stations, analogue
phones and ISDN-S0 buses connected to the system. CCS4-S board also supplies the
63 Veff – 20/25/50 Hz ringing voltage for the analogue sets.