Physical Details
Power Supplies
A.C Mains Input
This equipment is fitted with a wide-ranging power supply. It is suitable for voltages of 100-240VAC -10% +6% at 50/60 Hz
nominal.
Specification
Technical Earth
Item Specification
Height 44.5 mm chassis
Width 442.5 mm excluding fixing brackets
Overall width 482.6 mm including fixing brackets
Depth 550 mm excluding rear connector clearance
Rack mounting standard 1U x 19 inch (1U = 44.45mm)
Approximate weight 7.5 kg (16.5 lbs)
Item Specification
Power distribution system
Type TN ONLY (EN 60950-1 Annex V): Power distribution system which is
directly earthed, the parts of the equipment required to be earthed by
Protective Earthing Conductors. This equipment must NOT be used with
single-phase three-wire and PE, TT or IT Type Power distribution systems.
Connection to supply
Pluggable Equipment Type A (EN 60950-1 para 1.2.5): Equipment which is
intended for connection to the building power supply wiring via a non-
industrial plug and socket-outlet or a non-industrial appliance Coupler or
both. Correct mains polarity must always be observed. Do not use reversible
plugs with this equipment.
Class of equipment
Class I Equipment (EN 60950-
1 para 1.2.4): electric shock protection by basic
insulation and protective earth.
Rated voltage range 100-240 V AC (single phase)
Operating voltage range 90-254 V AC (single phase)
Voltage selection Wide ranging
Rated frequency range 50-60 Hz
Operating frequency range 48-63 Hz
Rated current 4.0 – 2.0A
Input connector CEE 22/IEC 3-pin male connector
Fuse
Fuse in live conductor in power input filter at rear of chassis. Do not use
reversible plugs with this equipment.
Fuse type
Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
Fuse current rating 5 A 250 V T HBC
Power consumption 40 W – 350 W (Depending on Options fitted)