Vista de pagina 150
Temperature Coding
Module
Please switch off and refer to Customer
Support.
Invalid
Parameter
MPEG2
Video
Coding
Module
Slot n
0 000A0003 655363
internal
Invalid Parameter received by the
Video/Audio Module. Please see Video
Encoder status for a more detailed
description of the error.
Video/Audio
Module Error
MPEG2
Video
Coding
Module
Slot n
0 000A0004 655364
internal
Video/Audio Module Error. Please see
Video Encoder status for a more
detailed description of the error.
Power On Self
Test Failure
MPEG2
Video
Coding
Module
Slot n
0 000A0006 655366
internal
At least one start-up test has failed.
Problems may be experienced with the
normal operation of the chassis.
Internal HW
Information
MPEG2
Video
Coding
Module
Slot n
0 000A0007 655367
internal
HW reported an unexpected status
value. This does not effect normal
operation of the chassis.
Option Card
Build Version
Mismatch
MPEG2
Video
Coding
Module
Slot n
0 000A0008 655368
internal
The software on this option card is not
an officially released version.
SMPTE334
Closed Captions
Input Lock
MPEG2
Video
Coding
Module
Slot n
1 000A0009 655369
input
No valid SMPTE334 Closed Captions can
be detected
Anc Bar Data
Input Lock
MPEG2
Video
Coding
Module
Slot n
1 000A000A
655370
input No valid bar data can be detected.
Video Input
Lock
MPEG2
Video
Coding
Module
Slot n
1 000A0005 655365
input
No valid video found on video input.
Please check source connection.
VBI teletext not
detected on input
VBI Slot n
1 000A0021 655393
input
Unable to find teletext data on all of the
configured lines. Please check the video
input. For more details on the type of VBI,
see the VBI status page.
VBI video index
not detected on
input
VBI Slot n
1 000A0022 655394
input
Unable to find video index data on any of
the configured lines. Please check the video
input. For more details on the type of VBI,
see the VBI status page.
VBI closed
captions not
detected on input
VBI Slot n
1 000A0023 655395
input
Unable to find closed caption data on any of
the configured lines. Please check the video
input. For more details on the type of VBI,
see the VBI status page.
VBI WSS not
detected on input
VBI Slot n
1 000A0024 655396
input
Unable to find WSS (ETSI or AFD) data on
any of the configured lines. Please check the
video input. For more details on the type of
VBI, see the VBI status page.
VITC not detected
on input
VBI Slot n
1 000A0025 655397
input
Unable to find VITC data on any of the
configured lines. Please check the video
input. For more details on the type of VBI,
see the VBI status page.
Selected Time
code source not
detected
VBI Slot n
1 000A0026 655398
input
For the selected Time code source no Time
code was found. If in auto mode no source
was found on any input. Make sure that the
correct source is configured.
Dolby E
Alignment
Audio
Module
Slot n
0 000A0030 655408
input
Dolby E frames not properly aligned to
video frames. May glitch on frame
drop/repeat.
Dolby E Input
Lock
Audio
Module
Slot n
0 000A0031 655409
input
No valid Dolby E found on selected
input.
Audio1 DD Pass
Thru sync loss
Audio
Module
Slot n
0 000A0041 655425
input
Audio and Video were not locked prior
to encoder input.
Audio1 Input
Lock
Audio
Module
Slot n
0 000A0042 655426
input
No valid audio found on selected input.
Please check source connection.
Audio1 ADS
Control Track
Audio
Module
Slot n
0 000A0043 655427
input
Control track for Audio Description not
present
Audio1 silence
Audio
Module
Slot n
0 000A0044 655428
input
Silent period detected. Valid only for
Audio Description Service encoding.
Audio1 loss of Audio Metadata input lost and encoder set to