A technical earth terminal is located at the rear panel of the chassis.
IP Output Transport Stream
The following parameters are controllable for each IP Output transport stream for each output port or ports depending on the
redundancy mode that is selected:
Control Ethernet Specification
Overview
The system has two Ethernet control ports, that support IEEE 802.3 100BASE-TX and 1000BASE-T Ethernet protocols. The Control
ports are accessible via RJ-45 connectors on the rear panel of the chassis and support IEEE 802.3u auto-negotiation and parallel
detection. Also, the ports support Auto-MDIX.
IP Parameters
It is possible to configure the following IP parameters for the Control Port
Parameter Description/Range Comment
Source IP Address aaa.bbb.ccc.ddd Source IP address
Subnet Mask aaa.bbb.ccc.ddd Source Subnet address
Source UDP Port 0 to 65535 Source IP Port Number
Destination IP Address aaa.bbb.ccc.ddd Destination IP address
Destination UDP Port 0 to 65535 Destination IP Port Number
Time To Live 0 to 240 TTL value for inclusion in the IP header
Type Of Service 0 to 255 ToS value for inclusion in the IP header
Item Specification
Connector type RJ-45 (100/1000 Base T)
Connector designation Ctrl 1/2
Pin outs
(Unused pins are not connected)
Pin 1 - Rx/Tx A(+)
Pin 2 - Rx/Tx A (-)
Pin 3 - Rx/Tx B (+)
Pin 4 - Rx/Tx C (+)
Pin 5 - Rx/Tx C (-)
Pin 6 - Rx/Tx B (-)
Pin 7 - Rx/Tx D (+)
Pin 8 - Rx/Tx D (-)
Parameter Description
IP Address xxx.xxx.xxx.xxx (Ipv4)
Network Mask xxx.xxx.xxx.xxx (Ipv4)
Gateway Address xxx.xxx.xxx.xxx (Ipv4)
© Ericsson AB 2011. All rights reserved
© Ericsson AB 2011. All rights reserved