Receiver Configuration
RX8200 Configuration Guide
10
3.5 CONFIGURATION OF NETWORK ACCESS
Access to the RX8200 should be configured on a client site as shown in Figure 2 above. The IP Data Output and
Management LAN connections should be connected directly to the WNE Server. IP Data and Management
functionality are completely separated on the RX8200, hence the requirement for separate network connections.
If a client environment requires multiple WNE server connections to a single RX8200 through a switch, then every
connected server will still require two individual connections as depicted in Figure 9 below.
Figure 9 Multiple WNE Servers & Single RX8200
3.6 CONFIGURATION OF RX8200 ON RLS BROWSER INTERFACE
Access the RX receiver through a browser window from the WNE server using its default IP address of
http://172.16.2.20. With a correctly configured Management IP address, the default Status page of the RX8200 will
be displayed.
Figure 10 RX8200 Bookmarks Toolbar Shortcut