16
3. Ensure Modem chips U4 and U19 are
19A704272P4. Required when upgrading to
Group 4 (or later), replace if necessary.
4. Ensure microprocessor U1 is the faster 80C320
(RYT 121 6060/A) device. This processor is
required when upgrading to Group 4 (or later).
Processor is available in Speedy Upgrade Kit
SPK9505. Replace if necessary. Refer to LBI-
38894 for installation instructions.
5. Ensure Turbo Board harness has Ferrite Toroid
installed. Toroid is included in the SPK9505
Speedy Upgrade Kit. Replace if necessary. Refer
to LBI-38822 for installation instructions.
6. Remove the old EPROM (U2) from the GETC
Logic Board.
7. Install the new EPROM into the XU2 socket, being
sure to properly orient the chip.
8. Power up the channel.
9. Download the proper Turbo software. Refer to
SRN1060, SRN1062, and LBI-38822.
10. Program the GETC’s personality and perform an
operational checkout using the procedures
contained in this manual and the detailed
instructions contained in TQ3357 and SRN1060.
TURBO BOARD SOFTWARE
INSTALLATION
This procedure provides instructions for downloading
the Turbo software. The software is included in the Station
Turbo media kit, 344A4414. The installation process
involves downloading the GETC1E utilities to an IBM
compatible personal computer (PC), and an interconnecting
cable (TQ-3360) to download the new software to the Turbo
Board.
When downloading 344A4414 Group 3 (and earlier)
software, the PC reads data from the files on the 344A4414
diskette and transfers the data to the Turbo Board
microprocessors through connectors J103 and J104 at the
rear of the GETC Shelf.
If the PC Programmer TQ3357 version 4 (or later) is
available, both the Turbo software and GETC personality
may be downloaded without changing setups. In addition,
the PC Programmer will diagnose any problems between the
PC and the GETC during the downloading process and
simplify the handling and archiving of the Turbo software.
Equipment Required
IBM PC/XT/AT or compatible with at least 640K
memory, monitor and keyboard running MS-DOS
version 3.0 or higher.
Hard disk is recommended; but, not required.
Serial Port configured as either COM1 or COM2.
TQ-3360 programming cable.
Male DB-25 to female DB-9 adapter or cable if the
PC's serial port connector is a male DB-9 connector
instead of a male DB-25 connector.
Software distribution diskette 344A4414G2 (or
later), refer to SRN1060and SRN1062 for software
compatibility.
Load1e Utility
Prepare the PC for programming the GETC Turbo
Board by performing the following steps:
1. Connect the TQ-3360 programming cable from the
PC's serial port connector to the GETC Shelf
connector J104 (A DB-25 to DB-9 adapter may be
needed.)
Loading Turbo Software with TQ3357 Version 4 (or
later)
1. Using the TQ3357’s LOAD utility, copy the
Station Turbo software (344A4414) into the PC
Programmer’s working directories.
2. Refer to TQ3357 “Upgrading Firmware With The
LOAD1E Utility” for complete instructions on
running load1e utility.
Loading the Turbo Software from DOS
1. Using standard DOS commands or a software file
manager, create a directory named "
LOAD1E
" on
the PC's hard drive.
2. Make "
LOAD1E
" the current directory and copy
the following files from the software diskette into
the "
LOAD1E
" directory:
load1e.exe
1etop.hex
1ecrc.hex
1ebot.hex