11
2.2.4.2. Link GETC Uplink/Downlink Requirements
Hardware Turbo Hardware Revision
Downlink Yes Rev. F or later for 19D902104
or
any rev. of 19D904266
Uplink No Rev. F or later for 19D902104
or
any rev. of 19D904266
2.2.4.3. SCAT GETC Requirements
Hardware Turbo Hardware Revision
SCAT Yes Rev. F or later for 19D902104
or
any rev. of 19D904266
2.2.5. Jessica Requirements
2.2.5.1. MD110 Requirements
Please refer to LBI-39039, EDACS Jessica PBX Gateway MD110 Configuration Manual, for MD110 requirements.
2.2.5.2. PI Requirements
The PI requirements are as follows:
T1
• MUX and MD110 connection ports are 100 ohm balanced.
E1
• MUX and MD110 connection ports are 120 ohm balanced.
2.2.5.3. MUX Requirements
The MUX provided with Jessica meets the following requirements:
T1
• 23 channels of balanced 600 ohm 4-wire audio (no signaling required).
• 1.544 Mb/s 100 ohm aggregate interface.
• T1 framing is extended superframe (ESF).
• T1 line coding is B8ZS.
• 120 VAC 50/60 Hz or 240 VAC 50/60 Hz is preferred.
• The unit will mount in a 19-inch rack.
• CCITT: G.703, G.704, G.711 (u-Law), G.733, G.734, and G.824.
• FCC Part 15 Class B approval is required.
• CSA and UL approval are required.