12
E1
• 30 channels of 4-wire balanced 600 ohm audio (no signaling required).
• 2.048 Mb/s 120 ohm impedance aggregate interface.
• HDB3 line coding.
• CCITT: G703, G704, G711 (A-Law), G732, G736, and G823.
• CISPR22: EN 55022.
• IEC: 801-2, 801-3, 801-5; EN 60950 per 950.
• The unit will mount in a 19-inch rack.
2.2.6. RF Repeater Requirements
The equipment may be EDACS MASTR II, MASTR IIe, or MASTR III.
2.2.7. Radio Requirements
• A radio must support digital interconnect dialing.
• Dual tone multi-frequency (DTMF) tone sending capability, while connected to a called party, is necessary for special
functions, such as voice mail access.
Interconnect must be enabled on each particular radio. In addition, the following settings are recommended.
Option
Setting
0-9 (tone length) 50 ms
Start Delay 200 ms
*,# length 100 ms
DTMF pause 500 ms
Interdigit delay 100 ms
2.2.8. Power Requirements for Jessica
AC power (adequate to meet system requirements, environmental control, and digital or voice grade lines) must be
available to the site prior to the installation. An unterminated power cord and a standard three-prong ground plug are
furnished for the PI cabinet power supply. Check to be sure that the power outlet complies with local ordinances.
The equipment should be connected to a good earth ground wire of adequate size. A ground stud is provided for a
separate cabinet ground.
Voltage Requirements Power Requirements Power Source
PI 110 VAC 50/60 Hz
or
220 VAC 50/60 Hz
150-200W Cabinet Power Supply
Terminal for PI 110 VAC 70W (estimated) 110 VAC outlet
MD110
(model /10 or /50)
110 VAC 50/60 Hz
or
220 VAC 50/60 Hz
300W (typical) 110 VAC or 220 VAC
outlet
Optional PC and
printer for MD110
110 VAC outlet 500W (estimated) 110 VAC outlet
MUX -48 VDC <35W Cabinet Power Supply