TX Power Settings
High Power Settings
1. The "Tx High Power Calibration" window should be on the screen.
If this window is not on the screen, then use the F1 Next or F2 Prev
keys to toggle to the correct window.
2. Press F4 Tx On to key the transmitter.
3. Measure the transmitter power output.
4. With the Low Frequency value highlighted, increment or decrement
the current value (Hex or Decimal) until the specified window for
power is reached. See Table 3.
5. Measure the total radio current. Current should be less than the high
power current specification given in the table. The tracking data for
each band segment will be updated with the displayed value upon
exiting the calibration application (pressing F10 to exit and F1 to
update tracking data).
6. Press the F4 Tx Off to unkey the transmitter.
7. Repeat this procedure for the remaining 5 frequencies.