4. Press F4 Tx Off to key the transmitter.
5. Repeat steps 2-6 for each frequency.
Table 5 - Data Deviation Specifications
FREQUENCY DEVIATION (kHz)
TX Low
3.0 ±0.1
TX Mid
3.0 ±0.1
TX High
2.4 ±0.1
From Data Modulation Window, your options are:
F1-Next Select this option if you want to:
Advance the screen to the next setting which can
be adjusted.
F2-Prev Select this option if you want to:
Return the screen to the previous setting which can
be adjusted.
F3-Decimal/Hex Select this option if you want to:
Toggle the input fields on the screen between
decimal and hexadecimal.
F4-Tx On/Tx Off Select this option if you want to:
Key or unkey the radio.
F9-Help Select this option if you want to:
Receive further information pertaining to a field
area.
Shift F9
Window Help
Select this option if you want to:
Receive further information pertaining to the pre-
sent window.
F10-Back Select this option if you want to:
Return to the Maintenance Screen.
LBI-38898