Ericsson EDACS MDX Manual del operador Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Table 2 - Band Segment Fequency Ranges And
Factory Calibration Frequencies
Frequency Band Range (MHz)
Factory Calibration
(MHz)
LOW 806-813 806.0125
MID 813-821 813.0125
HIGH 821-824 824.0125
LOW Talkaround 851-858 851.0125
MID Talkaround 858-866 858.0125
HIGH Talkaround 866-869 869.0125
All fields represent the TX frequency and are numeric. Make the
desired changes and press F10 Back to exit.
From the Calibration Frequencies Window, your options are:
F9-HelpSelect this option if you want to:
Receive further information pertaining to a field area.
Figure 3 - Calibration Frequencies Window
LBI-38898
9
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 27 28

Comentarios a estos manuales

Sin comentarios