SYSTEM HOOK-UP (PCS Only)
Connect all peripheral equipment to your computer prior to config-
uring the PC Programming Software items. Remember to refer to the
operating manuals of each device for correct installation procedures.
If your system is already established, check to see that you have all
the equipment necessary to execute the program. Isolate all cables con-
necting the computer to devices to prevent tangling, interference and
damage.
Table 1 - Tracking Data Parameters
PARAMETERS TYPICAL HEX VALUES
Squelch Openings
(All Bands)
B3
NORMAL
TX BAND
LOW
806-813 MHz
MEDIUM
813-821 MHz
HIGH
821-824 MHz
Power-High 7E 7F 7F
Power-Low 50 52 53
TX Modulation 27 26 1B
Data Modulation 28 27 1D
PARAMETERS TYPICAL HEX VALUES
TALKAROUND
TX BAND
LOW
851-858 MHz
MEDIUM
858-866 MHz
HIGH
866-869 MHz
Power-High 76 78 72
Power-Low 54 54 57
TX Modulation 2D 2B 20
Data Modulation ** ** **
** NOT USED