Configuration of Conditional Access Using XML File Download
<?xml version="1.0" encoding="UTF-8"?>
<simulcrypt_config>
<ecmg>
<scg>
<scg_id>0x100</scg_id>
<transport_stream_id>102</transport_stream_id>
<program_number>10</program_number>
<key_no>41</key_no>
</scg>
</ecmg>
<emmg>
</emmg>
</simulcrypt_config>
5.4.8 Simulcrypt
When Simulcrypt is being used (multiple ECM streams containing the same Control
Word), there will be multiple <ecm_group> definitions:
<?xml version="1.0" encoding="UTF-8"?>
<simulcrypt_config>
<ecmg>
<scg>
<scg_id>0x0</scg_id>
<transport_stream_id>101</transport_stream_id>
<cp_duration_ds>600</cp_duration_ds>
<program_number>10</program_number>
<key_no>128</key_no>
<ecm_group>
<ecm_id>0x0</ecm_id>
<super_cas_id>0x0000001</super_cas_id>
<access_criteria>00000011</access_criteria>
2/1553-FGC 101 1019 Uen A
5-15
Vista de pagina 110