Code Upgrade and License Key Entry
7.2.3 Software Upgrading
To upgrade the software:
1. Unzip/save upgrade files to a local directory.
2. Note IP address of EQ unit, make sure local PC can ping it.
3. Open a DOS session and navigate to the directory where the upgrade files are
saved.
4. Type ‘up xxx.xxx.xxx.xxx’ where ‘x’ is the IP address of the unit to be upgraded.
This runs a batch file that loads all the new code via FTP.
5. Wait until upgrade has finished (DOS prompt comes back).
6. Reboot unit to apply new software/firmware.
7.2.4 Output Card Upgrade
For details on upgrading of output Cards, see Chapter 9 of this Reference Guide.
7.3 License Key Entry to Enable/Disable Features
The unit is shipped with CA enabled if the option EQ8096/SWO/DVBCA has been
ordered at time of purchase.
The unit is shipped with M-CMTS enabled if the option EQ8096/HWO/DTI has been
ordered at time of purchase.
The unit is shipped with 1GHz capability enabled if the option
EQ8096/SWO/12QAM/1GHZ has been ordered at time of purchase.
If any of the options were not originally ordered, but is subsequently required it is
possible to enter a new license key to enable the option (M-CMTS will require
fitment of the DTI client card).
A license key can also be obtained to enable/disable Authentication (User name,
Password) access to the Web browser. Please contact TTV Customer Services for
details on this option.
7.4 Requesting a Key
To request a key:
1. Place an order for any of the options listed in Section 7.3, specifying the type of
license required on existing EQ8096 unit(s).
2. The order must include the unit serial number (found on the side of the unit or
reported on the status web page) and the corresponding unique serial number
for each unit that can be found on the web browser under:
Engineering Æ Advanced Parameter Functions Æ License Key Entry
2/1553-FGC 101 1019 Uen A
7-4
Comentarios a estos manuales