Operating the EQ8096 Using the Web Browser
• This page provides a means to apply a redundancy switch, causing all unit
outputs to be set to their inactive state.
• Default parameters can also be restored (excluding the Serial Number and
Control IP address parameters) and the connection will be maintained.
• This page also allows the configuration parameters to be read, the output being
a hex file.
• Selecting Flash FP LED will cause the unit front panel green LED to flash a few
times.
• XPO Config allows the user to retrieve the XPO configuration file.
• License key entry is primarily for factory use only, to enable licensed features
such as DVBCA.
• Standard Input Ports auto populates the TS pages with a fixed paradigm UDP
port assignment. The IP address/Multicast address used is the same as that
defined for the relevant Data Port.
• Data port primary reset forces the data ports back to their primary connection,
after a redundancy switch.
3.6.1.6 PSI Debug Functions
The PSI Debug Function is provided for engineering debug of the unit in unexpected
circumstances.
3.7 TS Input Assignments Tabbed Page
The TS Input Assignments tabbed page enables navigation to different Transport
Stream MAC assignment pages, as well as showing the number of enabled TS and
MAC source for each Output Card. By default Output Cards 1 and 2 are sourced by
MAC1, and Output Cards 3 and 4 via MAC2 etc.
Transport Stream MAC assignment is configured using the TS Construction page,
see Section 3.4.
Any-to-any mapping enables the unit to map any Transport Streams on any Input
Port to any RF Output Card QAM channel.
Note: The user is expected to keep a record of what MAC input source
corresponds to which Program within a Transport Stream.
2/1553-FGC 101 1019 Uen A
3-34
Comentarios a estos manuales