Preventive Maintenance and Fault-finding
6.4.4 Lithium Battery
The lithium battery fitted within this product is not user replaceable and as such
should only be replaced by qualified service personnel.
6.5 Power Supply Problems
6.5.1 Symptoms
Warning!
Do not attempt to service the Power Supply Unit as opening or removing covers
may expose dangerous voltages or other hazards. Refer all servicing to service
personnel who have been authorised by Ericsson.
Use the following techniques to fault-find the EQ8096 according to the observed
symptom(s) when a power supply failure is suspected.
6.5.2 Power LED Unlit
If the EQ8096 Power LED is unlit, fault-find the problem as detailed in Table 6.1.
Table 6.1 Power LED Unlit Fault-finding
Step Action If Result of Action is
Yes…
If Result of Action is
No…
1
Check Power LED. Is the
EQ8096 still working?
If the EQ8096 is clearly
working normally then
the Power LED itself is
probably at fault. Call a
Service Engineer.
Proceed to next step.
2
Check Power Source.
Connect a known-working
piece of equipment to the
power source outlet. Does
it work?
The problem lies within
the EQ8096 or power
cable. Proceed to next
step.
The problem lies with the
power source. Check
building circuit breakers,
fuse boxes, etc. If
problem persists, contact
the electricity supplier.
3
Check Power Cable and
Fuse. Unplug the power
connector from the
EQ8096 and try it in
another piece of
equipment. Does it work?
The problem lies within
the EQ8096. Proceed to
next step.
The problem lies with
either the cable itself, or
with the fuse in the plug.
Replace the fuse or try to
substitute another cable.