Operating the EQ8096 Using the Web Browser
3.1 Introduction
Standard configuration instructions are given in the User Guide. This chapter gives
further information on the operation of the unit and describes additional functions not
required for everyday operation.
3.2 Establishing a Connection
3.2.1 Assigning a Control IP Address
All EQ8096 units are shipped with an invalid Control Port IP address of 0.0.0.0. This
must be configured to a local valid IP address before the product can be fully
configured. This can be performed using the Front Panel Keypad (see Table 2.6) or
via RS-232:
1. Connect a cable between the Host Status port on the EQ8096
(9-way male D-Type) and a local PC using a straight through RS-232 cable.
2. Using a suitable terminal emulator on the PC, Set up the communication
parameters.
Note: The serial port communications defaults to 115200 bit/s, 8 bit data, no
parity, 1 stop bit.
3. Power cycle the EQ8096. The terminal emulator will display a boot sequence
that will show the software version and control port IP settings. If the IP address
is still at the factory default of 0.0.0.0 for all 4 ports, then the user will be required
to assign a valid address to any of these.
4. Using the terminal, the user should enter the local IP address allocated to the
unit using the command IPn xxx.xxx.xxx.xxx
(e.g. IP3 172.17.124.3) and then press return. ‘n’ is the control port index (1 – 4)
as outlined below:
a CA Main
b CA Redundant
c Control Main
d Control redundant
e The IP settings are effective immediately.
Note: Since the default Gateway IP address is not set in the unit, the user will only
be able to establish an Ethernet connection from an IP address on the same
Sub-net. See Section 3.2.2 for description of how to set Subnet mask +
gateway address.
2/1553-FGC 101 1019 Uen A
3-5