Ericsson 1553-FGC 101 1010 Uen A Guía de usuario Pagina 181

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 196
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 180
Technical Specification
B.1 Unit Specification
The EQ8096 Unit specification is shown in Table B.1. This may be subject to
change with further development.
Table B.1 EQ8096 Unit Specification
Item Specification
Inputs Gigabyte Ethernet
Interface
4 x Redundant pair RJ-45 or optional 4 x Redundant pair
SFP (Small Form-Factor Pluggable).
Capability
Process up to 4 fully loaded Gigabit Ethernet link
simultaneously.
Up to 4096 CBR or VBR single program Transport
Streams
Support for a single multi-program Transport Stream
per QAM
Support for Service dropping and PID
filtering/remapping
Support for multiplexing up to 4 SPTSs into an MPTS
Stream encapsulation in UDP (RFC 768) or RTP (RFC
3550)
Up to seven Transport Stream packets per IP datagram
Removes up to ±60 ms input jitter
Supports DOCSIS 3.0 DEPI MPT and PSP modes of
data encapsulation
Supports DTI Timestamp insertion and restamping
Support for unicast and multicast flows
PSIG support
Outputs
RF Performance Refer to Table B.5
Modulation
Characteristics
Refer to Table B.6
Processing
Dejittering of each incoming Transport Stream
Extraction of incoming PSI
PID remapping
Automatic generation and insertion of outgoing PSI
tables
MPEG-2 multiplexing of up to 96 multiple program
Transport Streams in accordance with ISO/IEC 13818-
1
2/1553-FGC 101 1019 Uen A
B-3
Vista de pagina 180