Installing the Equipment
Figure 2.4 Connector Block for -48 V DC Input (Without Fuse)
+
-
2.5.3 DC Connector Details
For connection to the –48 V input connector (shown in Figure 2.4) the following
parts from AMP or Molex should be used:
AMP Universal MATE-N-LOK
Housing: AMP no. 1-480700-0
Female terminal (3 needed per housing): AMP no. 926901-1
Molex MLX
Housing: Molex no. 50-84-1030
Female terminal (3 needed per housing): Molex no. 02-08-1002
2.5.4 Connection cable color coding
The DC input cable supplied with the product is color coded in accordance with the
following.
Table 2.3 DC Connector Wire Colors
Earth Green-and-yellow
–48 V Blue
0 V Brown
2.5.5 Connecting the Unit to a DC Power Supply
Note: This equipment is not intended for direct connection to centralized DC
power systems in the USA or Canada.
Connect the EQ8096 to the local DC power supply as follows.
1. Local DC Power Supply - Ensure the local DC supply is isolated.
2. EQ8096 - Ensure circuit protection of a suitable value is fitted to the product
supply wiring.
3. Supply Cord - Connect the DC lead to the EQ8096 input connector and then to
the local DC power supply. Switch on the DC power supply.
2/1553-FGC 101 1019 Uen A