Preventive Maintenance and Fault-finding
5. Tighten the four locking screws.
Notes: Following this procedure does NOT invalidate the warranty.
Obtain a replacement card by contacting Ericsson Customer Support.
Ensure that details of the suspected card are available beforehand.
6.5.5 Modulator Card Failure
Use Table 6.3 to aid in diagnosing a modulator card fault.
Table 6.3 Modulator Card Fault-finding
Step Action If Result of Action is
Yes…
If Result of Action is
No…
1
Check the status of
the Modulator Card.
Check that the
modulator card is
correctly installed and
configured. Is there a
modulator failure alarm
being shown on the
Status web page?
If the unit indicates a
critical failure, swap out
the card and retest. Refer
to
Section 6.5.6 for details.
If no modulator failure
alarm is shown, go to
Step 2.
2
Check the status of
the RF ports. Do the
ports reflect the reported
status?
Discuss the perceived
problem with Ericsson
Customer Support.
If the port is not providing
a valid output when it has
been enabled via the
Modulation Settings web
page, swap out the card
and retest. Refer to
Section 6.5.6 for details.
6.5.6 Hot Swapping a Modulator Card
Caution!
This equipment contains Electrostatic Sensitive Devices (ESDs). Appropriate
precautions must be observed. Suitable protective devices must be used or worn
before handling. Consult international standards or the manufacturer for further
details
Please refer to Chapter 9 ‘Upgrading EQ8096 with Input and Output Option Cards’.
Notes: Following this procedure does NOT invalidate the warranty.
Obtain a replacement card by contacting Ericsson Customer Support.
Ensure that details of the suspected card are available beforehand.