Alarms
4.4 Specific Alarms
4.4.1 Serial Number Alarm
The serial number is unique and set at manufacture. It corresponds with the number
printed on the side of the unit to assist in unit identification. It is also used to
configure the MAC addresses of the Ethernet ports.
The alarm indicates that the serial number of the unit has not been set or has been
reset to 0. In this case the MAC addresses will not be unique (other units with no
serial number set will have the same MAC addresses).
The serial number is factory-set.
Figure 4.4 Serial Number Alarm Web Page
4.4.2 Data Connection Alarms
An alarm is raised if there is no physical data connection.
Table 4.4 describes the items carried on the Data Connection Alarms web page.
Table 4.4 Items on the Data Connection Alarms Web Page
Parameter Description
Data Connection
Provides an indication of the line status of the selected data port. A
loss of line activity generates a Data connection alarm
4.4.3 Modulator Alarms
This page allows modulator alarms to be masked/unmasked and also allows the
level of alarm severity to be selected.